TEST RESULTS — 1200 Series
Results Summary
Applied Load
per Foot of Wall
(Distributed as shown in diagram above)
Max
Deflection
Calculated Shear at Mud Line
Calculated Moment
(max)
lbs / ft
in
lbs / ft
ft
·
lbs/ft
1855
0.423
1007
3021
3726
0.949
2022
6066
5625
1.517
3054
9162
7290
2.136
3957
11871
9543
2.403
5180
15540
* The weld holding the 6" stud to the steel channel at the top of wall failed, ending the test.